Hey there! As a supplier of Wound Core Type Transformer, I often get asked about how tap changers work in these bad boys. So, I thought I'd write up a blog post to break it down in a way that's easy to understand.
Let's start with the basics. A wound core type transformer, as the name suggests, has a core that's wound using a continuous strip of electrical steel. This core design offers some pretty neat advantages, like lower core losses and better efficiency compared to traditional laminated cores. That's why they're a popular choice in Energy Efficient Distribution Transformers.
Now, onto the tap changer. In simple terms, a tap changer is a device that allows you to adjust the turns ratio of the transformer. Why would you want to do that? Well, the voltage in an electrical grid can fluctuate for various reasons, like changes in load demand or the distance from the power source. These voltage variations can cause problems for the electrical equipment connected to the grid. For example, if the voltage is too high, it can damage sensitive electronics; if it's too low, the equipment might not function properly.
A tap changer helps to maintain a stable output voltage by changing the number of turns in either the primary or secondary winding of the transformer. There are two main types of tap changers: off - load tap changers (OLTC) and on - load tap changers (OLTC).
Off - load Tap Changers (OLTC)
The off - load tap changer is the simpler of the two. As the name implies, you have to take the transformer offline before you can make any adjustments. This means shutting down the power supply to the transformer. It's not the most convenient option, but it's also pretty cost - effective.
Here's how it works. The transformer's winding has a series of taps at different points along the coil. These taps represent different numbers of turns. When you want to change the turns ratio, you physically move the connection from one tap to another. For example, if you move the connection to a tap with fewer turns in the primary winding, the turns ratio decreases. According to the transformer equation (V_p/V_s = N_p/N_s) (where (V_p) is the primary voltage, (V_s) is the secondary voltage, (N_p) is the number of turns in the primary winding, and (N_s) is the number of turns in the secondary winding), a decrease in the turns ratio will result in an increase in the secondary voltage.
Off - load tap changers are typically used in applications where the voltage doesn't change frequently. For instance, in some small - scale industrial plants where the load remains relatively stable over long periods. But if you need to make frequent voltage adjustments, an off - load tap changer won't cut it. That's where on - load tap changers come in.
On - load Tap Changers (OLTC)
On - load tap changers are more sophisticated and allow you to change the turns ratio while the transformer is still in operation. This is crucial in applications where a stable voltage is required at all times, like in large commercial buildings or power distribution networks.
The operation of an on - load tap changer is a bit more complex. It uses a set of switches and a transition resistor to ensure a smooth changeover between taps without causing a significant interruption in the power supply. When you want to switch taps, the on - load tap changer first connects the transition resistor to the circuit. The transition resistor helps to limit the current during the tap - changing process. Then, it gradually disconnects the connection from the old tap and connects it to the new tap. Once the connection to the new tap is secure, the transition resistor is removed from the circuit.
This process happens very quickly, usually in a matter of milliseconds, so the impact on the power supply is minimal. On - load tap changers can be either mechanical or electronic. Mechanical on - load tap changers use physical contacts to make and break the connections, while electronic on - load tap changers use solid - state devices like thyristors. Electronic on - load tap changers are generally faster and more reliable, but they're also more expensive.
Why Tap Changers Matter in Wound Core Type Transformers
In wound core type transformers, tap changers play a vital role in optimizing the performance. Since these transformers are often used in Energy Efficient Distribution Transformers, maintaining a stable voltage is essential for maximizing energy efficiency. By adjusting the turns ratio, the tap changer can ensure that the transformer operates at its optimal point, reducing losses and saving energy.
Moreover, tap changers also enhance the flexibility of the transformer. They allow the transformer to adapt to different grid conditions and load requirements. For example, if the load on the grid increases, the tap changer can adjust the voltage to ensure that the electrical equipment receives the right amount of power.
Other Types of Transformers in Our Portfolio
As a supplier, we don't just offer wound core type transformers. We also have a range of other transformers, like Dry Cast Resin Transformers, Oil Filled Distribution Transformers, and Dry Distribution Transformer.
Dry cast resin transformers are a great choice for indoor applications where safety is a concern. They use a resin - filled insulation system, which is non - flammable and environmentally friendly. Oil - filled distribution transformers, on the other hand, are known for their high power capacity and long service life. They use oil as an insulating and cooling medium. Dry distribution transformers are similar to dry cast resin transformers but have a different insulation design.


Let's Talk Business
If you're in the market for a transformer, whether it's a wound core type transformer with a tap changer or any of the other types we offer, I'd love to have a chat with you. Our team of experts can help you select the right transformer for your specific needs and provide you with all the technical support you need. Don't hesitate to reach out for a quote or to discuss your requirements. We're here to make sure you get the best - in - class transformer solution for your application.
References
- Electric Power Systems: A Conceptual Introduction by Bruce R. Parker
- Power System Protection and Switchgear by C. N. Karassik